| R&D
Environment for Cat.6 Connecting Hardware |
 |
Final
Testing |
| |
Telebox Industries
Corp. has very extensive electrical high frequency
testing of produced
connecting hardware, which is documented as
either pass/fail result or with recording
of tested
electrical parameters in the full specified
frequency range. Failing components are offered
to the
customer with documented performance data.
Frequency of testing depends on component
type and experience, but no documented
sampling
procedure is present at Telebox Industries
Corp.
The following data for final testing at Telebox
Industries Corp. has been concluded by 3P:
|
| |
•
|
Visual
inspection: |
100
% |
| •
|
Continuity
(dc) testing: |
100
% |
| •
|
Testing
for Shorts: |
100
% |
| •
|
Near
End Crosstalk measurements: |
10 %
- 100 %
(most of the sampling is only recorded
as fail/pass) |
| •
|
Insertion
Loss, Return Loss and
Far End Crosstalk measurements: |
Type
testing |
| •
|
High
Voltage testing and Insulation
Resistance Measurements: |
Type
testing |
|
| |
Test results are stored
in the quality department for three years.
The following instruments were applied at
Telebox Industries Corp. for performing the
ongoing
quality assurance testing: |
| |
High Frequency
Testing: |
| |
- HP Network Analyzer, type 8753E
- Agilent ENA Network Analyzer, type
E5062A
- BH Electronics Baluns, types 040-0092
and 040-0093
- North Hills Baluns, type 0322 BFX
|
| |
|
| |
dc Resistance and
Short Circuit Testing: |
| |
- Microtest dc test equipment, type CT-8687
- Microtest dc test equipment, type CT-8681
- Wayne Kerr LCR Meter, type 4273
- Chen Hwa Milliohmmeter, type 502AC
- Instek AC/DC Withstand Voltage / Insulation
Tester, type GPI-735
|
| |
|